13. Manual Control: This shall be realized by key operated. switch to provide a fixed cyclic switching from phase to phase, as programmed locally but without interfering with any preset safety time such as amber, minimum green and all red.
a. Flashing Mode: In amber flashing mode the amber aspects of vehicle signal groups shall flash, while all other signals are extinguished. The local controller shall be forced into this operation mode by:
Operational mode switch.
External signal received from the central equipment.
The protection circuits, when conflicting greens are sensed.
14. Control Panel: The control panel shall provide the following functions: Switch: Manual/Automatic operation
Flashing Amber
Lamps on/Lamps off
Isolated/coordination operation shall be by the controller
receiving a command from the Master or by loss of communication. Key operated
switch: Phase step
15. Options:The controller shall accommodate the following functions: Dimming facility for 3 kVA load
Output voltages: 200-160-120 Pedestrian Demand facility
Indication Panel
Detector Unit
Housing: The equipment shall be housed in a weatherproof steel cabinet.
Provide circuit breaker(s) for terminating service wire. Circuit breaker(s) shall have minimum, 15 ampere rating.
Provide convenience receptacle in each cabinet. Receptacle to be a single German style 2 pin with ground (Legrand type 74130) outlet so located that by use of a socket attachment, a 60 watt lamp can be plugged in to provide light without disturbing any other equipment.
Provide an equipment grounding bus in each controller cabinet and ground the bus to the cabinet.