螺紋
Mates with connector
與連接裝置緊密配合
Dimensions in Milimeters (inches in Brackests)
尺寸為毫米 (括號(hào)內(nèi)為英寸)
SAE 螺紋傳感器
螺紋-5、8-18
螺孔鉆尺寸-37/64
部件編號(hào) 直徑尺寸A 插入深度 直徑B 全長(zhǎng) 直徑C
尺寸為毫米 (括號(hào)內(nèi)為英寸)
公制螺紋傳感器
螺紋-M16X1.5-6g
螺孔鉆尺寸-14.5¢mm
部件編號(hào) 直徑尺寸A 插入深度 直徑B 全長(zhǎng) 直徑C
- - - -
- - - -
- - - -
- - - -
- - - -
尺寸為毫米 (括號(hào)內(nèi)為英寸)
最大可用帶刻痕鎖緊螺母的螺紋長(zhǎng)度
Barber Colman Company
 安裝,操作和維護(hù)手冊(cè) F7307
  16/04/2008
12.23 速度傳感器
萬(wàn)能轉(zhuǎn)速轉(zhuǎn)換器和萬(wàn)能傳感器
操作手冊(cè)
型號(hào):SST-2000A/H, SST-2200A/H, SST-2400A/H
此處描述的規(guī)格和信息的變更不再另行通知。Dynalco Controls公司保留對(duì)此中描述設(shè)備改進(jìn)功能或者設(shè)計(jì)進(jìn)行修改的權(quán)利。盡管包含在這本手冊(cè)里的信息已經(jīng)通過(guò)仔細(xì)評(píng)審并認(rèn)為非?煽,Dynalco Controls公司不承擔(dān)任何因應(yīng)用而產(chǎn)生或者設(shè)備中描述的專(zhuān)業(yè),間接發(fā)生的,意外時(shí)間,或者間接損失的責(zé)任。此處的擔(dān)保不超過(guò)被擔(dān)保產(chǎn)品支付的價(jià)格。
版權(quán)@2001。 版權(quán)所有。
商標(biāo)
SST 2000A /H,SST 2200A,SST-2400H Dynalco Controls公司。
Dynalco Controls公司N.W.第53大街3690號(hào),
堡壘勞德代爾,佛羅里達(dá)33309美國(guó)
8 (954) 739-4300
傳真(954) 484-3376
美國(guó)印刷
關(guān)于您的速度轉(zhuǎn)換器2
模型4
特色4
規(guī)格5
第2章 SST-2000A-/H 9 安裝
安裝裝置10
關(guān)于電氣連接10
連結(jié)信號(hào)輸入11
第三章 外部設(shè)備動(dòng)力裝置 13
為SPD-100提供動(dòng)力、SPD-700、或其它頻率儀器14
使用DPM-105測(cè)量?jī)x表作為外部速度指示計(jì)14
為零速度加速和其它負(fù)荷提供動(dòng)力16
驅(qū)動(dòng)SPV-200 螺線管氣閥17
第4章 速度轉(zhuǎn)換器校驗(yàn)19
找到編程接通指令20
改變量程輸入頻率范圍21
輸入頻率范圍不到80赫茲量程21
輸入頻率范圍比20,000赫茲量程21
校驗(yàn)SST-2000A-/H 22
校驗(yàn)4-20 mA 成比例輸出24
編程確定點(diǎn)和繼電器25
調(diào)整信號(hào)敏感性27
響應(yīng)時(shí)間28
調(diào)整個(gè)別設(shè)定值28
確定設(shè)定值31
調(diào)整設(shè)定值32
入門(mén)指南
第一章
關(guān)于速度轉(zhuǎn)換器
警告
SST2000A-/H速度轉(zhuǎn)換器系列/傳感器作為主要的過(guò)速停車(chē)裝置使用時(shí),必須定期進(jìn)行測(cè)試;
* SST-2000A-/H系列為速度轉(zhuǎn)換器系列/傳感器速度接通/發(fā)送器為主要的過(guò)速和速度不足進(jìn)行的進(jìn)行模式,啟動(dòng)和停車(chē)裝置進(jìn)行管理控制:
* 發(fā)動(dòng)機(jī)
* 機(jī)器
* I/P 裝置
* 器械操作
* 制造過(guò)程控制
* 記錄
* 測(cè)量
它是怎樣工作的
SST-2000A-/H 能接受從0-0.1赫茲(每分鐘6 脈沖)到0-50,000赫茲的全值頻率輸入值;標(biāo)準(zhǔn): 0-80赫茲到0-20,000赫茲。
輸入裝置的示例包括:
* 被動(dòng)或者主動(dòng)磁性加速
* 軸角編碼器
* 接點(diǎn)閉合
* 流量計(jì)
* 光電發(fā)射管
速度轉(zhuǎn)換器將頻率輸入(速度,比率)轉(zhuǎn)變?yōu)榫性比例dc輸出:
* 0-1 mA(標(biāo)準(zhǔn)-測(cè)量?jī)x表輸出)
* 4-20 mA(標(biāo)準(zhǔn)-成比例輸出)
* 0-5 Vdc (選擇轉(zhuǎn)換器)
* 0-10 Vdc (選擇轉(zhuǎn)換器)
提供0,2,或者4中繼變壓器設(shè)定值(取決于模型類(lèi)型)
入門(mén)指南
結(jié)構(gòu)尺寸
圖1-1  SST-2000A-/H的俯視圖和側(cè)面圖;尺寸采用英寸以及(厘米)。
同時(shí)提供專(zhuān)門(mén)的防爆外殼組件(用硬件安裝完成);參見(jiàn)XP第6頁(yè)的外殼標(biāo)準(zhǔn) Connect ungrounded cable shield to 4
連接地下電纜屏護(hù)和4;
Rcute relay power wiring separately from other wiring
將繼電器電源線和其它線路分開(kāi)
(原文不清)
Repeater output
中繼器輸出;
Jumper to 11 for contact closure signal
接觸閉合信號(hào)的跨接線11;
Jumper to 7 to disable alarms
警報(bào)失效跨接線7;
Jumper to 7 to reset or prevent latching
裝置重設(shè)或者自動(dòng)關(guān)閉跨接線7;
Verify set point
確定設(shè)定值;
Diameter
直徑;
模型
模型 設(shè)定值編號(hào) 第三方認(rèn)證
A 系列-標(biāo)準(zhǔn)繼電器
SST-2000A  CSA: 一般證明LR 92270
ABS:獲準(zhǔn)型號(hào)
CE:89/336 /EEC,輕工業(yè):
CE:2/23 /EEC,低電壓指令SST-2200A  
SST-2400A  
H-系列 密閉繼電器
SST-2000A  CSA:等級(jí)I,區(qū)域2,Grp. D LR 45322*
CE: 89/336 /EEC,輕工業(yè):
CE:2/23 /EEC,低電壓指令
SST-2200A  
SST-2400A  
* 證明根據(jù)CSA認(rèn)證范圍內(nèi)的SST-2000H 系列設(shè)備而定。
特性
信號(hào)源 1.場(chǎng)地程序傳感器,包括觸點(diǎn)閉合輸入,電磁式拾波器ac 發(fā)電機(jī)、接點(diǎn)閉合、光電管;
輸入頻率 *從0-0.1赫茲(6脈沖數(shù)/分鐘)到0-20 kHz的全值。*可調(diào)整領(lǐng)域的范圍和靈敏度。
警報(bào)設(shè)定值 SST-2000A/H (在需要比例輸出的條件下)
2 SST-2200A/H
4 SST-2400A/H
警報(bào)設(shè)定 警報(bào)可配置范圍的過(guò)速,速度不足,供電,鎖定,以及自動(dòng)設(shè)定 。
警報(bào)的再設(shè)定 *瞬間對(duì)所有的鎖定警報(bào)進(jìn)行設(shè)定;
*將所有的鎖定警報(bào)永久轉(zhuǎn)化為自動(dòng)設(shè)定;
設(shè)定值的驗(yàn)證 完整的驗(yàn)證要求在沒(méi)有對(duì)繼電器啟動(dòng)的情況下,進(jìn)行查看和設(shè)定;要求采用外用表;
比例輸出 0-1mA 和 4-20mA (標(biāo)準(zhǔn))0-5Vdc;
0-5Vdc或0-10Vdc(安段選擇)
輸出功率 中繼器輸出驅(qū)動(dòng)計(jì)數(shù)器和自力轉(zhuǎn)速表。調(diào)節(jié)14 Vdc輸出功率; 主動(dòng)加速,附件和測(cè)量表(e.g.DPM-105;MTH-103D; SPD-100L; LST-100L);
輸出范圍 包括50mAdc的輸出電源
規(guī)格
電力
輸入信號(hào)頻率范圍 *0-20 kHz(標(biāo)準(zhǔn))(可調(diào)整領(lǐng)域)
* 0-0.1赫茲(特別訂貨單)
* 0-80赫茲(特別訂貨單)
* 4 0-50 K 赫茲(特別訂貨單)
波形 *可接受脈沖,正弦曲線,插圖,TTL,或CMOS;
輸入信號(hào)敏感度 *25 mVrms(標(biāo)準(zhǔn)工廠設(shè)定)
*5mVrms 給100mVrms(可調(diào)整領(lǐng)域)
*50Vrms(最大量適合標(biāo)準(zhǔn)單位)
*1.0伏特(要求輸入信號(hào)減敏)的閥值
輸入阻抗 *接近無(wú)線低的信號(hào)電平
*信號(hào)在10 kQ(Min.)超過(guò)+15.0 V峰值,-1.0 V峰值;
功率輸入 *115 Vac±%,47-420赫茲
* 22-30 Vdc,最大的5W或者150 mAdc
* 220 Vac,50/60赫茲(可選擇)
比例輸出 *0-1 mAdc(標(biāo)準(zhǔn))
* 4-20 mAdc(標(biāo)準(zhǔn))
* 0-5 Vdc或0-10Vdc(可選領(lǐng)域;對(duì)于20 kQ或更高的外部負(fù)載電阻而言);
可提供定制范圍
最大負(fù)荷
* 1 kQ與11 5 / 220 Vac或30 Vdc電源
* 750歐姆與22 Vdc電源
* 線路為22 至30 Vdc
輸出電流 獨(dú)立的負(fù)載電阻至額定負(fù)載電阻
范圍、零-可調(diào)節(jié) 全值±5%(最小值)
輔助表輸出 比例0-1 mAdc,濾波,因?yàn)閮x表或記錄器負(fù)荷為750 ∩。
電源輸出 調(diào)節(jié)+14 Vdc?%; 40 mAdc(最大負(fù)荷);
復(fù)示器輸出 方波14 V峰值-峰值,零基,正向
輸出脈動(dòng)和噪音 0.1%的超過(guò)的10%到100%最大量的全值。
響應(yīng)時(shí)間 150毫秒,10%到90% (標(biāo)準(zhǔn))。 全值頻率范圍低于80赫茲為較慢比例。
線性穩(wěn)定 小于0.05% 全值隨10% 變化范圍內(nèi)的電源電壓發(fā)生;溫度系數(shù):01%°F(±018%°C);
Product; Information
DYNA Power Controls
Magnetic Speed Sensors
13.8mm [.545]  ~ Dia.       ,  r   '  19 mm 0.5mm        , — [.75] Hex.        Thread -*- [.020]       /      LocknUt          /  
Dimens [Inch
15.88mm
[.625]-24 NEF-2AThread
Mates with Connector
MS3106-10SL-4S
Sensors With SAE Threads
Thread —5/8-18 Tap Drill Size —37/64
Part No.  Size Dim. A  Insertion Depth Dim. B*  Overall Length Dim. C
DYNT-10300  28 mm [1-1/8]  19 mm [3/4]  57 mm [2-1/4]
DYNT-10100  63 mm [2-1 /2]  54 mm [2-1/8]  89 mm [3-1/2]
DYNT-10400  76 mm [3]  66 mm [2-5/8]  102 mm [4]
DYNT-10200  101 mm [4]  92 mm [3-5/8]  127 mm [5]
DYNT-10600  127 mm [5]  118 mm [4-5/8]  152 mm [6]
DYNT-10500  .152 mm [6]  142 mm [5-5/8]  178 mm [7]
Dimensions are in millimeters with inches in brackets [
Sensors With Metric Threads
Thread —M 16X1.5—6g
Tap Drill Size — 14.50mm ^^t
Part No.  Size Dim. A  Insertion Depth Dim. B*  Overall Length Dim. C
DYNT-11300  28 mm [1-1/8]  19 mm [3/4]  57 mm [2-1/4]
DYNT-11100  63 mm [2-1/2]  54 mm [2-1/8]  89 mm [3-1/2]
DYNT-11400  76 mm [3]  66 mm [2-5/8]  102 mm [4]
DYNT-11200  101 mm [4]  92 mm [3-5/8]  127 mm [5]
DYNT-11600  127 mm [5]  118 mm [4-5/8]  152 mm [6]
DYNT-11500  152 mm [6]  142 mm [5-5/8]  178 mm [7]
Dimensions are in millimeters with inches in brackets [   ] 'Maximum usable thread length with locknut against knurl.
Barber-Colman Company
PRECISION DYNAMICS DIVISION
1354 CIHlord Avenue
P.O. Box 2940
Loves Park, IL U.S.A. 61132-2940
Phone: (815)877-0241 Telex: 4330365
In Europe contact: Co/man Nederland B.V., Maalderi/30, 1185 ZC Amstelveen, The Netherlands. Phone: (020) 45-51-57,    Telex: 15419 COL NE NL
srapi
iHr 1  INSTALLATION,  OPERATION AND MAINTENANCE MANUAL  F7307  16/04/2008
12.23      Speed transmitter
ST3411:792390096-01
SST-2000 Series
UNIVERSAL SPEED SWITCH •& TRANSMITTER
An Operator's Guide
For models: SST-2000A/H, SST-2200A/H, SST-2400A/H
Copyright
Specifications and information herein are subject to change without notice. Dynalco Controls reserves the right to make changes to the equipment described herein to improve function or design. Although the information contained in this manual has been carefully reviewed and is believed to be reliable, Dynalco Controls does not assume any liability for special, indirect, incidental, or consequential damages arising out of the application or use of the equipment described herein. Warranty is limited and cannot exceed the price paid for the product upon which the warranty is based.
Copyright © 2001. All rights reserved.
Trademarks
SST-2000A/H, SST-2200A, SST-2400H are trademarks of Dynalco Controls.
Dynalco Controls
3690 N.W. 53rd Street,
Fort Lauderdale, FL 33309 U.S.A.
8 (954) 739-4300
Fax (954) 484-3376
Printed in U.S.A.
p/n!45F-11761
Contents
Chapter 1     Getting Started 1
About your speed switch 2
Models 4
Features 4
Specifications 5
Chapter 2     Installing the SST-2000A/H 9
Mounting the unit 10
About Electrical Connections 10
Connecting Signal Inputs 11
Chapters     Powering External Devices 13
Powering an SPD-100, SPD-700, or other frequency instruments 14
Using DPM-105 meters as external speed indicators 14
Powering Zero Velocity Pickups and Other Loads 16
Driving an SPV-200 Solenoid Pneumatic Valve 17
Chapter 4    Calibrating the Speed Switch 19
Locating the programming switch instructions 20
Changing the full-scale input frequency range 21
Input frequency range less than 80 Hz full-scale 21
Input frequency range greater than 20,000 Hz full-scale 21
Calibrating the SST-2000A/H 22
Calibrating the 4-20 mA Proportional Output 24
Programming Set Points and Relays 25
Adjusting Signal Sensitivity 27
Response Time 28
Adjusting Individual Set Points 28
Verifying Set Point Values 31
Adjusting Set Point Values 32
in
Chapter 1 
About your speed switch
WARNING
When the SST-2000A/H Series Speed Switch/Transmitter is used as the primary overspeed shutdown device, it must be tested regularly.
The SST-2000A/H series is a speed switch and signal transmitter that provides alarm set points for over- and underspeed control for sequential, startup, and shutdown switching for:
* engines
* machines
* I/P drivers
* instrumentation
* process control
* recording
* measurement
How it works
The SST-2000A/H accepts a full-scale frequency input value from 0-0.1 Hz (6 pulses per minute) to 0-50,000 Hz. Standard: 0-80 Hz to 0-20,000 Hz.
Examples of input devices include:
* passive or active magnetic pickups
* shaft encoders
* contact closures
* flow meters
* photocells
The speed switch converts frequency input (speed, rate) into linear proportional dc outputs:
* 0-1 mA (standard - meter out)
* 4-20 mA (standard - proportional out)
* 0-5 Vdc (switch selectable)
* 0-10 Vdc (switch selectable)
It provides 0, 2, or 4 relay trip set points (depending on the model
Getting Started
Physical Dimensions
Fig. 1-1    Top and side view of the SST-2000A/H. Dimensions in inches and (centimeters).
Special explosion proof housings kits (complete with mounting hardware) are also available. See XP rated housings on page 6.
8.25 (20.9)
7.75 (19.7)
3.62 (9.2)
1.81 (4.6)
3.25 (8.2)
0.25 (0.63) DIAMETER
Dimensions in inches (centimeters)
Chapter 1
Models
Features
Model  No. Of Set Points  3rd Party Certification(s)
A series - standard relays
SST-2000A  0  CSA: general certification LR 92270 ABS: type approval CE: 89/336/EEC, Light Industrial CE: 72/23/EEC, Low Voltage Directive
SST-2200A  2  
SST-2400A  4  
H series - hermetically sealed relays
SST-2000H  0  CSA: Class I, Div. 2, Grp. D, LR 45322* CE: 89/336/EEC, Light Industrial CE: 72/23/EEC, Low Voltage Directive
SST-2200H  2  
SST-2400H  4  
* Approval contingent upon housing an SST-2000H series device in a CSA-certified enclosure.
Signal Sources
Input Frequency  Field-programmable for: sensors, including contact closure input, magnetic pickups, ac generators, contact closures, photocells.
 * Full-scale values from 0-0.1 Hz (6 pulses/minute) to 0-20 kHz. * Field-adjustable range and sensitivity control.
Alarm Set Points
Alarm Settings
Alarm Disable
Alarm Reset
Set Point Verification  0   SST-2000A/H (when only proportional output is required) 2   SST-2200A/H 4   SST-2400A/H
 Alarms are field-configurable for overspeed, underspeed, energize, de-energize, latch, auto-reset.
 Disable all alarms (for startup conditions and special functions)
 * Momentarily reset all latched alarms * Permanently converts all latching alarms to auto-reset
 Integral VERIFY permits viewing and setting of set point value without actuating the relays. Requires an external meter.
Proportional Outputs
Output Power
Output Range  0-1 mA and 4-20 mA (standard) 0-5 Vdc or 0-10 Vdc (field-selectable)

 Repeater output drives counters and self-powered tachometers. Regulated 14 Vdc output powers active pickups, accessories, and meters (e.g. DPM-105; MTH-103D; SPD-100L; LST-100L).
 Current source up to 50 mAdc output always included.
Getting Started
Specifications
Electrical
Input Signal Frequency Range
Waveforms
Input Signal Sensitivity
Input Impedance
Power Input  * 0-20 kHz (standard) (field-adjustable) * 0-0.1 Hz (special order) * 0-80 Hz (special order) 4 0-50K Hz (special order)

 * Accepts pulsed, sinusoidal, square, TTL, or CMOS

 * 25 mVrms (typical factory setting) * 5 mVrms to 100 mVrms (field-adjustable) « 50 Vrms (maximum for standard units) « 1.0 volt threshold (requires input signal desensitizing)

 « Nearly infinite at low signal levels « 10 kQ (min.) at signals exceeding +15.0 V peak, -1.0 V peak

 * 115 Vac ±10%, 47-420 Hz * 22-30 Vdc, maximum 5 W or 150 mAdc * 220 Vac, 50/60 Hz (optional)
Proportional Output
Output Current Span/zero adj.
Auxiliary Meter Output
Supply Output
Repeater Output
Output Ripple and Noise
Response Time
Linearity Stability  * 0-1 mAdc (standard) * 4-20 mAdc (standard) * 0-5 Vdc or 0-10Vdc (field-selectable; for external load resistance of 20 kQ or higher)
» Custom ranges available
MAXIMUM LOAD * 1 kfi with 11 5/ 220 Vac or 30 Vdc power * 750 ohms with 22 Vdc power * linear between 22 and 30 Vdc
 Independent of load resistance up to the rated load resistance
 ±5% (minimum) of full-scale
 Proportional 0-1 mAdc, filtered, for meter or recorder loads up to 750 H.
 Regulated +14 Vdc ±5%; 40 mAdc (maximum load)
 Square wave 14 V peak-to-peak, zero based, positive going
 0.1% of full-scale maximum over 10% to 100% of full-scale.
 150 milliseconds, 10% to 90% rise (standard). Full-scale frequency ranges below 80 Hz are proportionally slower.
 0.1% of full-scale (0.05%, typical), all outputs.
 Less than 0.05% of full-scale change with a 10% change in supply voltage. Temp, coeff. ±0.01% per °F (±0.018% per °C)